FREE Encyclopedia of Building & Environmental Construction, Diagnosis, Maintenance & Repair No ChatBot Pledge: The accuracy & trustworthiness of every InspectApedia article or Q&A is researched by human experts.
"The Trouble With Aluminum Wiring," Consumer Reports, January, 1981, p. 42
"The Use of Aluminum Conductors with Electrical Wiring Devices in Electrical
Wiring Systems," Underwriters Laboratories, Inc., 333 Pfingsten Road,
Northbrook, IL 60062, Issued March 1973, reissued July 1980
J. Aronstein, "Reducing the Fire Hazard in Aluminum-Wired Homes,"
Wright-Malta Corporation, Ballston Spa, NY, Jan. 25, 1982
Information on Aluminum Wiring for Home Inspectors
D.J. Friedman, "Safety Considerations for the Electrical Inspector," The ASHI
Technical Journal of home inspection and in-service building component
failures, Vol. 2 No. 1, Winter, 1992
D.J. Friedman, "Aluminum Wiring Poses Potential Fire Hazard," The Journal of
Light Construction, June 1996 [Reprinted in the ASHI Reporter, January 1997,
p.10-11]
Field Surveys of Aluminum Wiring Hazards & Failures
"National Controlled Study of Relative Risk of Overheating of Aluminum
Compared with Copper Wired Electrical Receptacles in Homes and Laboratory,"
Executive Summary. Prepared for U.S. Consumer Product Safety Commission.
Report #F-C4812-01, Franklin Research Center, Philadelphia, PA, April 20,
1979
R. Newman and W.H. King, Jr., "Pilot Survey of Branch Wiring Systems in
Montgomery County, Maryland," U.S. Consumer Product Safety Commission, Sept.,
1977
J. Aronstein, "Summary Report, Study of Overheating of Aluminum-Wired
Electrical receptacles in Scarborough, Toronto, Homes," Wright-Malta
Corporation, Ballston Spa, NY, Jan. 11, 1982
Aluminum Wiring Connectors/Connections
Aronstein, Jesse., and W. Campbell. "Overheating failures of aluminum-wired special service connectors." IEEE Transactions on Components, Hybrids, and Manufacturing Technology 6, no. 1 (1983): 8-15.
H. Dupre, "The Problems Involved in Designing Connectors for Aluminum Cable,"
Misc. Paper no. 51-325, AIEE Fall General Meeting, October, 1951.
J. Aronstein and W.E. Campbell, "Overheating Failures of Aluminum-Wired
Special Service Connectors," IEEE Trans. Components, Hybrids, and Mfg. Tech.,
V. CHMT-6 No. 1, Mar. 1983
N.T. Bond, "Reliability in Electrical Terminations on Aluminum Conductors,"
Electrical Products Div., Alcoa Conductor Products Co., Alcoa Laboratories,
Massena, NY.
C.W. Zimmerer and F.Neumer, "Aluminum Building Wires and Connectors,"
Bulletin of Research, No. 48, Underwriters Laboratories Inc., Sept. 1954
J. Aronstein and W.E. Campbell, "The influence of Corrosion Inhibitor and
Surface Abrasion on the Failure of Aluminum-Wired Twist-on Connections," IEEE
Trans. Components, Hybrids, and Mfg. Tech., V. CHMT-7 No. 1, March, 1984.
R. Schubert, "Erratic Behavior of Al/Al Wire Junctions," Elecrical Contacts -
1986, Proceedings of the 32nd IEEE Holm Conference on Electrical Contacts,
Boston, 1986.
"Test of 'Old Technology' Aluminum Wire With Twist-On Connectors," Project
Report CPSC-C-79-0079, Task II, for U.S. Consumer Product Safety Commission.
Wright-Malta Corp., Ballston Spa, NY, November 23, 1981
J. Aronstein, "Overheating Failures of Presently-Listed Aluminum Wiring
Connection Combinations Within Rated Service Conditions". Wright-Malta
Corp., Ballston Spa, NY, November 23, 1981
Kaiser Aluminum, ALUMINUM TYPE NM? HERE'S HOW [PDF] (1965) Ten Years Cleared the Way for Easier, Better Wiring, IAEI Magazine, September 1965, courtesy of Douglas Hansen CodeCheck
Watch out: the company later abandoned these instructions, they should NOT be used today.
Watch out: the company later abandoned these instructions, they should NOT be used today.
R.L. Hicks, "Pigtail Splicing Connections for Baseboard Heaters and Similar
Cyclic Loads," Ontario Hydro, Research Division
Failure Mechanisms of Aluminum Wiring
Aronstein, Jesse, and Doug Lee. "Selection Criteria for Residential Aluminum Connections." In 2012 IEEE 58th Holm Conference on Electrical Contacts (Holm), pp. 1-8. IEEE, 2012.
Aronstein, J. "Evaluation of a Setscrew Connector for Aluminum Wire." In Electrical Contacts-2007 Proceedings of the 53rd IEEE Holm Conference on Electrical Contacts, pp. 123-129. IEEE, 2007.
Aronstein, Jesse, and Thomas K. Hare. "AC and DC electromigration failure of aluminum contact junctions." IEEE Transactions on Components and Packaging Technologies 28, no. 4 (2005): 701-709.
Aronstein, J. "Performance classification for electrical connections using ASTM B868." In Proceedings of the Fifty-First IEEE Holm Conference on Electrical Contacts, 2005., pp. 162-166. IEEE, 2005.
Aronstein, J. "An updated view of the aluminum contact interface." In Proceedings of the 50th IEEE Holm Conference on Electrical Contacts and the 22nd International Conference on Electrical Contacts Electrical Contacts, 2004., pp. 98-103. IEEE, 2004.
Aronstein, J., and R. Butturini. "Evaluation of crimped terminations and splices in in-wall electric heaters." In Proceedings of the Forty-Eighth IEEE Holm Conference on Electrical Contacts, pp. 252-258. IEEE, 2002.
Aronstein, Jesse. "Analysis of field failures of aluminum-copper pigtail splices made with twist-on connectors." In Electrical Contacts-1999. Proceedings of the Forty-Fifth IEEE Holm Conference on Electrical Contacts (Cat. No. 99CB36343), pp. 87-93. IEEE, 1999.
Aronstein, Jesse. "Environmental conditions of residential electrical connections." In Electrical Contacts-1998. Proceedings of the Forty-Fourth IEEE Holm Conference on Electrical Contacts (Cat. No. 98CB36238), pp. 230-238. IEEE, 1998.
Aronstein, Jesse. "Evaluation of a twist-on connector for aluminum wire." In Electrical Contacts-1997 Proceedings of the Forty-Third IEEE Holm Conference on Electrical Contacts, pp. 46-56. IEEE, 1997.
Aronstein, J. "AC and DC electromigration in aluminum." In Electrical Contacts-1996. Proceedings of the Forty-Second IEEE Holm Conference on Electrical Contacts. Joint with the 18th International Conference on Electrical Contacts, pp. 311-320. IEEE, 1996.
Aronstein,J. "Electromigration Failure of Aluminum Contact Junctions,"
Elecrical Contacts - 1995, Proceedings of the 41st Annual Meeting of the
Holm Conference on Electrical Contacts, Montreal, 1995.
Aronstein, J. "Evaluation of receptacle connections and contacts." In Proceedings of IEEE Holm Conference on Electrical Contacts, pp. 253-260. IEEE, 1993.
Aronstein, J. "Environmental deterioration of aluminum-aluminum connections." In Electrical Contacts-1992 Proceedings of the Thirty-Eighth IEEE Holm Conference on Electrical Contacts, pp. 105-111. IEEE, 1992.
Aronstein, J. "Failure of Aluminum Connections in Residential Applications,"
Elecrical Contacts - 1991, Proceedings of the 37th Annual Meeting of the Holm
Conference on Electrical Contacts, Chicago, 1991.
Aronstein, J. "Conduction in failing aluminum connections." In Thirty-Sixth IEEE Conference on Electrical Contacts, and the Fifteenth International Conference on Electrical Contacts, pp. 479-486. IEEE, 1990.
Aronstein, J. "Conduction in Failing Aluminum Connections," Electrical
Contacts - 1990, Proceedings of the 36th IEEE Holm Conference on Electrical
Aronstein, J., and T. K. Hare. "Conduction through surface films on aluminum wire." In Electrical Contacts, 1988., Proceedings of the Thirty Fourth Meeting of the IEEE Holm Conference on Electrical Contacts, pp. 173-178. IEEE, 1988.
Aronstein, J. "Evaluation of a plated aluminum wire for branch circuit applications." In Electrical Contacts-1987, p. 107. 1987.
Aronstein, Jesse, and W. Campbell. "Evaluation of an aluminum conductor material for branch circuit applications." IEEE transactions on components, hybrids, and manufacturing technology 8, no. 1 (1985): 105-108.
Aronstein, Jesse, and W. Campbell. "The influence of corrosion inhibitor and surface abrasion on the failure of aluminum-wired twist-on connections." IEEE transactions on components, hybrids, and manufacturing technology 7, no. 1 (1984): 20-24.
Aronstein, Jesse, and W. Campbell. "Overheating failures of aluminum-wired special service connectors." IEEE Transactions on Components, Hybrids, and Manufacturing Technology 6, no. 1 (1983): 8-15.
Aronstein, Jesse., and W. Campbell. "Failure and overheating of aluminum-wired twist-on connections." IEEE Transactions on Components, Hybrids, and Manufacturing Technology 5, no. 1 (1982): 42-50.
Aronstein, J. Test of'Old Technology'Aluminum Wire With Twist-On Connectors. Project Report CPSC-C-79-0079, Task 11, for US Consumer Product Safety Commission. Wright-Malta Corp., Ballston Spa, NY, 1981.
Beland, Bernard, and Denis Saucier. "Fire damage to aluminum wired receptacles." Fire technology 22, no. 4 (1986): 341-345.
Braunovic, Milenko, Nikolai K. Myshkin, and Valery V. Konchits. Electrical contacts: fundamentals, applications and technology. [PDF] CRC press, 2006.
Braunovic, M. "Stress relaxation of aluminum wire conductors." In Electrical Contacts-1998. Proceedings of the Forty-Fourth IEEE Holm Conference on Electrical Contacts (Cat. No. 98CB36238), pp. 239-251. IEEE, 1998.
Braunovic, M. "Fretting Corrosion Between Aluminum and Different Contact
Materials," Electrical Contacts - 1977, Proceedings of the 23rd Annual
Meeting of the Holm Conference on Electrical Contacts, Chicago, 1977.
Braunovic, M. "Effect of Fretting on the Contact Resistance of Copper,
Aluminum, and Nickel-Coated Aluminum Wire Connections," Wear, V. 112, 1986.
Bond, N.T., D.L. Robinson, and M. Mohajery, "Fundamental Considerations of
Aluminum Electrical Contact Interfaces," Elecrical Contacts - 1977,
Proceedings of the 23rd Annual Meeting of the Holm Conference on Electrical
Contacts, Chicago, 1977.
Contacts meeting jointly with the 15th International Conference on Electrical
Contacts," Montreal, 1990.
Ferrino-McAllister, J. L., Richard J. Roby, and J. A. Milke. "Heating at electrical contacts: Characterizing the effects of torque, contact area, and movement on the temperature of residential receptacles." Fire technology 42, no. 1 (2006): 49-74.
Leger, M. "Metallurgical Analysis of Failed CO/ALR Devices," Ontario Hydro,
#78-54-K, Ontario, Canada, February, 1978.
Electrical Contacts meeting jointly with the 18th International Conference on
Electrical Contacts," Chicago, September 1996
Schoft, Stephan. "Measurement and calculation of the decreasing joint force in high current aluminum joints." In Proceedings of the 50th IEEE Holm Conference on Electrical Contacts and the 22nd International Conference on Electrical Contacts Electrical Contacts, 2004., pp. 511-518. IEEE, 2004.
Schoft, Stephan, Josef Kindersberger, and Helmut Löbl. "Reduction of joint force by creep in high current joints." In Proceedings of the 21th Conference on Electrical Contacts, pp. 406-412. 2002.
Shea, John J. "Glowing contact physics." In Electrical Contacts-2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts, pp. 48-57. IEEE, 2006.
Nickel Plated Aluminum Wire
H.O. Hansson, "Sinipal: Swedish-bred Aluminum Substitute for Copper Wire,"
Wire and Wire Products, September, 1970.
J. Aronstein and T.K. Hare, "Evaluation and Analytical Electron Microscopy
Investigation of a Plated Aluminum Wire for Branch Circuit Applications,"
IEEE Transactions on Components, Hybrids, and Manufacturing Technology, V.
11, No.2, June 1988, p. 218-226
J. Aronstein and W.E. Campbell, "Evaluation of an Aluminum Conductor Material
for Branch Circuit Applications," IEEE Trans. Components, Hybrids, and Mfg.
Tech., V. CHMT-8 No. 1, Mar. 1985
Connector/connection standards and test methods
UL Standard 1567, Underwriters Laboratories, Inc., Northbrook IL
(CO/ALR Wiring Device Terminals for Aluminum Wire)
UL Standard 486C, Underwriters Laboratories, Inc., Northbrook IL
(Splicing Connectors for Aluminum Wire)
ASTM B812-90, "Standard Test Method for Resistance to Environmental
Degradation of Electrical Pressure Connections Involving Aluminum and
Intended for Residential Applications," ASTM, 1916 Race Street, Philadelphia,
PA
Industry Handbooks
"Aluminum Building Wire Installation Manual and Design Guide," The Aluminum
Association, Inc.
Government Agency Documents
Bunten, Elaine D., John L. Donaldson, Eugene C. McDowell, HAZARD ASSESSMENT of ALUMINUM ELECTRICAL WIRING in RESIDENTIAL USE [PDF] Product Systems Analysis Division
Institute for Applied Technology
National Bureau of Standards
Washington, D. C. 20234 (1974) prepared for the U.S. Consumer Product Safety Commission, Washington D.C. 20207 , retrieved 2019/04/26 original source: https://nvlpubs.nist.gov/nistpubs/Legacy/IR/nbsir75-677.pdf
Watch out: the suggestion, made in 1974, of the Bunten paper that the aluminum wiring hazard could not be assessed were later supplanted by substantial data indicating that aluminum wiring was a significant fire hazard in homes. - Ed.
Abstract: In the mid- 1960s, aluminum wire began to be used in
significant quantities for residential branch- circuit wiring.
Reports of problems from various localities in the U.S. raised
serious concern and controversy as to the safety of this application. An official determination on this matter is within the
jurisdiction of the Consumer Product Safety Commission. This
report reviews the history of the use of aluminum in residential
wiring and describes the characteristics essential to data to
be used to evaluate the performance of aluminum wiring in the
field.
The examination of existing field data shows that no available data have the characteristics necessary to develop a reliable estimate of the level of risk to consumers associated
with aluminum wiring. Neither can the available data be used
to establish the relative risk of aluminum con^ared to copper
wiring. There is only a gross estimate of the extent to which
aluminum wiring is now in use in U. S. residences. Statistically
sound estimates of risk would be possible only after data
collection on a large scale.
Denver CO, & cited in Florida Building Code, ALUMINUM ELECTRICAL WIRING, [PDF] Fire Prevention & Investigation Division, Denver Fire Department, Department of Safety (2001) - retrieved 2019/04/26 original source http://www.floridabuilding.org/fbc/commission/fbc_0411/electrical_tac/aluminum_wiring.pdf
Watch out: the advice in this document that CO/ALR or AL/CU connectors as acceptable is NOT recommended by the US CPSC and risks fire or injury
R. Newman, "Hazard Analysis of Aluminum Wiring," April, 1975, U.S. CPSC,
NIIC-0600-75-H006
J.T. Wilson, "Report of the Commission of Inquiry
on Aluminum Wiring," Ontario, Canada,
March, 1979
J. Aronstein, "Tests of 'Old Technology' Aluminum Wire," Wright-Malta Corp.
Project Report CPSC-C-81-1418, U.S. Consumer Product Safety Commission,
Washington, DC, Feb. 10, 1983
Aluminum Electrical Wiring Hazards, Inspection, Repair Procedure documents available on Internet:
J. Aronstein, "Fire Due to Overheating Aluminum Wired Branch Circuit
Connections," Electrical Safety Conference, Univ. of Wisconsin-Extension,
Madison, WI, April 7, 1981
Contact Addresses for Requesting Information
The American Society of Home Inspectors, ASHI 847-290-1919
85 West Algonquin Road 847-290-1920 FAX
Arlington IL 60005-4423
https://InspectAPedia.com/home_inspection/Contact_ASHI.php
The Aluminum Association,
900 19th St.
NW, Washington DC 20006
NFPA - (National Fire Protection Association)
1 Batterymarch Park
P.O. Box 9101
Quincy, MA 02269-9101
UL - Underwriters Laboratories Inc.
333 Pfingsten Road
Northbrook, IL 60062
NEMA -National Electrical Manufacturers Association
2101 L Street, N.W.
Washington, DC 20037 202-457-8400 FAX 202-457-8411
Internat. Assoc. of Elect. Insp. 214-235-1455
901 Waterfall Way, Suite 602 214-235-3855
Richardson, TX 75080 6226,563 CIS
The Journal of Light Construction 802-434-4747
RR2 Box 146 jlc@bginet.com
Richmond VT 05477
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Questions & answers or comments about where to find the most authoritative information about aluminum electrical wiring in homes: hazards, history, inspection, troubleshooting & repair procedures. .
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed:if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted. Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.
In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.