InspectAPedia.com InspectAPedia®

Question? Just ask us!

Google
InspectAPedia

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

  • HOME
  • AIR CONDITIONING
  • DAMAGE ASSESSMENT
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



InspectAPedia ® Home

STRUCTURAL INSPECTIONS & DEFECTS

AGE of a BUILDING - how to determine
AIR BYPASS LEAKS
ANIMAL ODORS IN buildings
ARCHITECTURE & BUILDING COMPONENT ID
ASBESTOS IDENTIFICATION IN buildings

BASEMENT CEILING VAPOR BARRIER
BASEMENT HEAT LOSS
BEST CONSTRUCTION PRACTICES GUIDE
Best Interior Finish Practices
BLOWN-IN INSULATION
BOOKSTORE - INTERIORS
BUILDING NOISE DIAGNOSIS & CURE

CARPENTER ANTS
CARPENTER BEES
CARPETING & INDOOR AIR QUALITY
CARPETING, SELECTION & INSTALLATION
CEILING FINISHES INTERIOR
CRAWL SPACES

DECK & PORCH CONSTRUCTION
DRYWALL HAZARDS, CHINESE
DRYWALL INSTALLATION Best Practices

EFFLORESCENCE, Salts & White / Brown Deposits
ELDERLY & VETERANS HOME SAFETY
ENGINEERED WOOD Flooring

FIBERGLASS INSULATION
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOOR TYPES & DEFECTS
FRAMING DAMAGE, INSPECTION, REPAIR
FRAMING DETAILS for BETTER INSULATION

GAS DETECTION INSTRUMENTS

HEAT LOSS in BUILDINGS
HEAT LOSS DETECTION TOOLS
HEAT LOSS INDICATORS
HEAT LOSS PREVENTION PRIORITIES
HEAT LOSS R U & K VALUE CALCULATION
HOUSEWRAP AIR & VAPOR BARRIERS
HOUSE DOCTOR, how-to be
HUMIDITY LEVEL TARGET

INDOOR HOUSE DUST & DEBRIS
INSECT INFESTATION / DAMAGE
INSULATION CHOICES
INSULATION LOCATION - WHERE TO PUT IT

KIT HOMES, Aladdin, Sears, Wards, Others
KITCHEN & BATH DESIGN GUIDE

LIGHTING, EXTERIOR GUIDE
LIGHTING, INTERIOR GUIDE
LOG HOME GUIDE

METAL LATH, PLASTER & STUCCO
MOBILE HOME INSPECTIONS
MOISTURE CONTROL in BUILDINGS
MOLD: A COMPLETE GUIDE TO MOLD
MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD CLEARANCE INSPECTIONS
MOLD COUNT NUMBER GUIDE
MOLD CONSULTANTS / INSPECTORS
MOLD CULTURE TEST KIT VALIDITY
MOLD DETECTION & INSPECTION GUIDE
MOLD or INDOOR AIR EMERGENCY RESPONSE
MOLD EXPERT, WHEN TO HIRE
MOLD FAQ's
MOLD LEVEL IN AIR, VALIDITY
MOLD ODORS, MUSTY SMELLS
MOLD PREVENTION GUIDE
MOLD RELATED ILLNESS GUIDE
MOLD SAFETY WARNINGS
MOLD SPRAYS, SEALANTS, PAINTS
MOLD STANDARDS
MOLD TEST KITS
MOLD TESTING METHOD VALIDITY

Nanomaterials Hazards
NOISE / SOUND DIAGNOSIS & CURE
NOISE, AIR CONDITIONER COMPRESSOR
NOISE, DUCT VIBRATION DAMPENERS
NOISE CONTROL for HEATING SYSTEMS
NOISE CONTROL for FLOORS
NOISE CONTROL for PLUMBING
NOISE CONTROL for ROOFS
NOISES COMING FROM WATER HEATER

ODORS & SMELLS DIAGNOSIS & CURE

PAINT FALURE, DIAGNOSIS, CURE, PREVENTION
PASCAL CALCULATIONS
PLASTER & BEAVERBOARD & DRYWALL
PLASTER BULGES & PILLOWS
PLASTER LATH, METAL
PLASTER, LOOSE FALL HAZARDS
PLASTER TYPE IDENTIFICATION
PLASTER VENEER Best Practices

RADIANT BARRIERS
RADIANT HEAT
RADIANT HEAT Floor Mistakes to Avoid
RADIANT HEAT TEMPERATURES
RADIANT SLAB FLOORING CHOICES
RADIANT SLAB TUBING & FLUID CHOICES
ROOF VENTILATION SPECIFICATIONS

SAFETY HAZARDS & INSPECTIONS
SAFETY: Elderly & Veterans Home Safety
SEARS KIT HOUSES
SINKING BUILDINGS
SLAB CRACK EVALUATION
SOUND CONTROL in buildings
Splits in Structural Wood Beams
STAIRS, RAILINGS, LANDINGS, RAMPS
STAIR FALL & TRIP HAZARDS

TERMITES
TRIM, INTERIOR INSTALLATION
TRUSS UPLIFT, ROOF
TRUSSES, Floor & Roof

VAPOR BARRIERS & CONDENSATION in BUILDINGS

WALL SIDING TRIM & FINISHES
WALL FINISHES INTERIOR
WALL CONSTRUCTION BARRIER vs CAVITY
WATER BARRIERS, EXTERIOR BUILDING
WATER ENTRY in buildings
WIND WASHING INSULATION At EAVES
WINDOWS & DOORS
WINTERIZE A BUILDING
WOOD, COAL STOVES & FIREPLACES
WOOD STOVE SAFETY

ZONE DAMPERS
ZONE VALVES

More Information

Stairway headroom clearance requirements (C) D Friedman Eric Galow Guide to Stair Headroom Clearances for Stair Construction & Inspection
     

  • Stair headroom or overhead clearance specifications & codes
    • Stairway Height, Width, Headroom Requirements
    • Sketches of stair headroom clearance design requirements
  • Stair dimensions: width height &c - separate article
  • STAIR HEADROOM
  • STAIR RISER SPECIFICATIONS - separate article
  • STAIR TREAD DIMENSIONS - separate article
  • Questions & Answers about stair codes & requirements for stair or step minimum width & headroom
  • References

Click to Show or Hide Related Topics

  • STAIRS, RAILINGS, LANDINGS, RAMPS - home
  • ATTIC STAIRS
  • BALUSTERS, STAIR & RAILING
  • BALUSTER INSTALLATION
  • BARK SIDE UP on DECKS & STEPS
  • BASEMENT STAIRS & WALKOUT COVERS
  • BOOKS on STAIR CONSTRUCTION
  • CABLE RAILINGS & GUARDRAILS
  • CHECKLIST for STAIR INSPECTIONS
  • CIRCULAR & CURVED STAIRS
  • CODES for STAIRS
  • COLOR / LIGHTING CUES AVOID TRIP HAZARDS
  • DECK STAIR BUILDING START
  • DECK STAIR BUILDING DETAILS
  • DECK & PORCH GUARDRAILINGS
  • EXTERIOR STAIRS
  • FIRE STOPPING for STAIRWAYS
  • FRAMING TRIANGLES & CALCULATIONS
  • GRASPABILITY of HANDRAILINGS
  • GUARDRAILS on BALCONIES, DECKS, LANDINGS
  • HANDRAILS & HANDRAILINGS
  • LIGHTING OVER STAIRS
  • PET STAIRS, PET RAMPS
  • PLATFORMS & LANDINGS, ENTRY & STAIR
  • RAILINGS
  • RAILINGS, DECK & PORCH
  • RAMPS, ACCESS
  • SLIP TRIP & FALL HAZARD LIST, STAIRS
  • SLIPS , TRIPS & FALLS, EXTERIOR STAIRS
  • SLIPPERY STAIRS, WALKS
  • SNAG HAZARDS on STAIRWAYS
  • STAIR DIMENSIONS, WIDTH, HEIGHT
  • STAIR RAILS, STAIR GUARDS
  • STAIR RISE & RUN CALCULATIONS
  • STAIR HEADROOM
  • STEP RISER DIMENSIONS
  • STEP TREAD DIMENSIONS
  • STEP TREAD NOSE DIMENSIONS
  • STRINGER DEFECTS, STAIR
  • WINDER or ANGLED STAIRS
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Stairway headroom & width codes & requirements: this document provides building code specifications, sketches, photographs, and examples of the stair passage width & stair overhead clearance or head room needed for indoor or outdoor stairs. How much space is needed over steps or stairs, and exactly where should those measurements be taken?

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

Stairway Height, Width, Headroom Requirements

Stairway Lighting requirements (C) Carson Dunlop

Stairway overall height, width, and headroom requirements & codes are detailed here. For a complete list of articles on stairs, railings, and ramps, their inspection, trip hazards, and good design, see STAIRS, RAILINGS, LANDINGS, RAMPS - INSPECTIONS, CODES. Or see these detailed articles on specifications for proper dimensions for stairs, railings, platforms

Stair dimensions: width height &c
  STAIR HEADROOM
  Stairway landings
  Stair Rise & Run Calculations
  Stair stringer defects
  Step riser dimensions
  STAIR TREAD DIMENSIONS
  Stair tread nose dimensions
HANDRAILS & HANDRAILINGS

Our page top photo, courtesy Galow Homes and Eric Galow, shows where headroom clearance should be measured at a stairwell: stair overhead clearance is the vertical distance measured between the outer edge of the stair tread surface (close to the stair tread rounded nosing), and the under-side of the ceiling above.

Specifications for Stairway Overhead Clearance: Headroom

Stairway headroom clearance requirements (C) D Friedman Eric Galow

  • Stairway headroom should be greater than or equal to six feet eight inches between the stair tread upper surface measured at the tread outer edge, and the ceiling above.

    Stairway headroom should be => 6'8" over tread or landing
  • Stairway maximum height (the total rise of the stairway from level floor to level floor) should be limited to twelve feet between floors if no landings are included.

Re-stating this for clarity:

Stair way headroom should be 12' or less between floors - or restated, the total rise for a set of steps between floors should be less than or equal to twelve feet.

This means landings could be required if the total rise height of a stairway is more than 12 ft.

Sketch at left provided courtesy Carson Dunlop Associates.

Model & Example California Building Code Specifications for Stairway Headroom Requirements

Every stairway must have a headroom clearance of not less than 6'8" measured vertically from the plane of the tread nosing to the soffit above at all points. [37]

...


Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Questions & answers or comments about stair codes & requirements for headroom over steps or stairways.

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • Carson, Dunlop &
Associates Ltd., TorontoCarson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. (416) 964-9415 1-800-268-7070 info@carsondunlop.com. The firm provides professional home inspection services & home inspection education & publications. Alan Carson is a past president of ASHI, the American Society of Home Inspectors. Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home. Carson Dunlop Associates' provides:
    • Commercial Building Inspection Courses - protocol ASTM Standard E 2018-08 for Property Condition Assessments
    • Home Inspection Education Courses including home study & live classes at eleven colleges & universities.
    • Home Inspection Education Home Study Courses - ASHI@Home Training 10-course program.
      Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on these courses: Enter INSPECTAHITP in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
    • The Home Reference Book, a reference & inspection report product for building owners & inspectors.
      Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
    • The Home Reference eBook, an electronic version for PCs, the iPad, iPhone, & Android smart phones.
      Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter inspectaehrb in the order payment page "Promo/Redemption" space.
    • The Illustrated Home illustrates construction details and building components, a reference for owners & inspectors.
      Special Offer: For a 5% discount on any number of copies of the Illustrated Home purchased as a single order Enter INSPECTAILL in the order payment page "Promo/Redemption" space.
    • The Horizon Software System manages business operations,scheduling, & inspection report writing using Carson Dunlop's knowledge base & color images. The Horizon system runs on always-available cloud-based software for office computers, laptops, tablets, iPad, Android, & other smartphones.
  • Eric Galow, Galow Homes, Lagrangeville, NY. Mr. Galow can be reached by email: ericgalow@gmail.com or by telephone: 914-474-6613. Mr. Galow specializes in residential construction including both new homes and repairs, renovations, and additions.

  • [1] Yale University Guidelines for Undergraduate Theatrical Productions and Special Events, Yale University’s Office of Undergraduate Productions, Office of the Fire Marshal, and Office of Environmental Health & Safety April 2005, web search 8/9/11, original source: http://www.yale.edu/oup/forms/pdf/guidelines.pdf
  • [2] CUE40303 Certificate IV in Live Production, Theatre and Events (Technical Operations), Australian Government, Department of Education, Employment, and Workplace Relations, web search 8/9/11, original source: https://www.training.nsw.gov.au/cib_vto/cibs/documents/cue40303.pdf
  • [3] Electrical Safety in the Theatre, Broadway Press, web search 8/9/11, original source: http://www.broadwaypress.com/PDFs/LTSpdfs/LTSchpt13.pdf - quoting:
    Referring to the NEC will provide the technician with details specifically related to the theatre and moreover, these regulations will
    be better suited to the needs of the theatre.
  • [4] Illustrated theatre production guide, John Holloway, Focal Press, 2002, ISBN 0240804937, 9780240804934
  • [5] How to Build Theater Stairs, an Illustrated Guide, Ben Teague, www.benteague.com, Amateur Theatre Division, December 2004, web search 8/9/11, original source: http://www.benteague.com/features/Stairs.pdf
    Note that Mr. Teague warns that his designs and advice do not comply with building codes.
  • [6] OSHA Publication 3124 - Stairways and Ladder, web search 12/21/11, OSHA Publications Office U.S. Department of Labor 200 Constitution Avenue, NW, N-3101 Washington, DC 20210 Telephone (202) 693-1888 or fax to (202) 693-2498. Original source: osha.gov/Publications/ladders/osha3124.html
  • [7] "The Elimination of Unsafe Guardrails, a Progress Report," Elliott O. Stephenson, Building Standards, March-April 1993
  • [8] "Are Functional Handrails Within Our Grasp" Jake Pauls, Building Standards, January-February 1991
  • [9] "The Elimination of Unsafe Guardrails, a Progress Report," Elliott O. Stephenson, Building Standards, March-April 1993
  • [10] Lighting, proper use of: proper aiming of a good flashlight can disclose hard to see but toxic light or white mold colonies on walls.
  • [11] The Stairway Manufacturers' Association, (877) 500-5759, provides a pictorial guide to the stair and railing portion of the International Residential Code. [copy on file as http://www.stairways.org/pdf/2006%20Stair%20IRC%20SCREEN.pdf ] -
  • [12] A HREF="http://astore.amazon.com/inspectapedia-20?node=14&page=2">Slips, Trips, Missteps and Their Consequences, Gary M. Bakken, H. Harvey Cohen, Jon R. Abele, Alvin S. Hyde, Cindy A. LaRue, Lawyers and Judges Publishing; ISBN-10: 1933264012 ISBN-13: 978-1933264011
  • [13] Steps and Stairways, Cleo Baldon & Ib Melchior, Rizzoli, 1989.
  • [14] The Staircase, Ann Rinaldi
  • [15] Common Sense Stairbuilding and Handrailing, Fred T. Hodgson
  • [16] Falls and Related Injuries: Slips, Trips, Missteps, and Their Consequences, Lawyers & Judges Publishing, (June 2002), ISBN-10: 0913875430 ISBN-13: 978-0913875438
    "Falls in the home and public places are the second leading cause of unintentional injury deaths in the United States, but are overlooked in most literature. This book is unique in that it is entirely devoted to falls. Of use to primary care physicians, nurses, insurance adjusters, architects, writers of building codes, attorneys, or anyone who cares for the elderly, this book will tell you how, why, and when people will likely fall, what most likely will be injured, and how such injuries come about. "
  • [17] Slips, Trips, Missteps and Their Consequences, Gary M. Bakken, H. Harvey Cohen, Jon R. Abele, Alvin S. Hyde, Cindy A. LaRue, Lawyers and Judges Publishing; ISBN-10: 1933264012 ISBN-13: 978-1933264011
  • [18] Slips, Trips, Missteps and Their Consequences, Second Edition, Gary M. Bakken, H. Harvey Cohen,A. S. Hyde, Jon R. Abele, ISBN-13: 978-1-933264-01-1 or ISBN 10: 1-933264-01-2, available from the publisher, Lawyers ^ Judges Publishing Company,Inc., www.lawyersandjudges.com sales@lawyersandjudges.com and also from the InspectAPedia Bookstore (Amazon.com)
  • [19] Arts, Crafts, & Theater Safety (ACTS), 181 Thompson Street, #23 New York, NY 10012-2586 Telephone: (212) 777-0062 E-Mail: ACTSNYC@cs.com, web search 5/9/12, website: http://www.artscraftstheatersafety.org/ - Quoting:
    ACTS is a not-for-profit corporation that provides health, safety, industrial hygiene, technical services, and safety publications to the arts, crafts, museums, and theater communities. A part of the fees from our consulting services goes to support our free and low-cost services for artists. We gratefully accept donations, but do not solicit them from the artists who call here for help and advice. We recognize that artists and performers are among the least affluent groups in society.
    ACTS also will not accept money or take advertising in our publications from manufacturers of artists materials or businesses whose interests could conflict with ours. We want artists to know that we have no financial incentive to make our product and safety recommendations.
  • [20] Access Ramp building codes:
    • UBC 1003.3.4.3
    • BOCA 1016.3
    • ADA 4.8.2
    • IBC 1010.2
  • [21] Access Ramp Standards:
    • ADA (Americans with Disabilities Act), Public Law 101-336. 7/26/90 is very often cited by other sources for good design of stairs and ramps etc. even where disabled individuals are not the design target.
    • ANSI A117.4 Accessible and Usable buildings and Facilities (earlier version was incorporated into the ADA)
    • ASTM F 1637, Standard Practice for Safe Walking Surfaces, (Similar to the above standard
  • [22] The Circular Staircase, Mary Roberts Rinehart
  • [23] Construction Drawings and Details, Rosemary Kilmer
  • [24]"The Dimensions of Stairs", J. M. Fitch et al., Scientific American, October 1974.
  • [25] Mobile Home Inspections common defects unique to factory built housing, inspection methods, The National Institute of Standards and Technology, NIST (nee National Bureau of Standards NBS) is a US government agency - see www.nist.gov
  • [26] The Art of Staircases, Pilar Chueca
  • [27 Building Stairs, by pros for pros, Andy Engel
  • [28] A Simplified Guide to Custom Stairbuilding, George R. Christina
  • [29] Basic Stairbuilding, Scott Schuttner
  • [30] The Staircase (two volumes), John Templar, Cambridge: the MIT Press, 1992
  • [31] The Staircase: History and Theories, John Templar, MIT Press 1995
  • [32] Steps and Stairways, Cleo Baldon & Ib Melchior, Rizzoli, 1989.
  • [33] BUILDING, FIRE, RESIDENTIAL CODES - The 2007 & 2010 California Building Code (Part 2), California Residential Code (Part 2.5) and the California Fire Code (Part 9) of Title 24 are available for viewing online via the following International Code Council web site link: California Codes, Title 24, Part 1, 6, 8, 10, 11 & 12 are also available for viewing and download in PDF form on the California website: 2007 Edition of the California Building Codes or see2010 Edition (Effective Jan. 1, 2011) of the California building codes. For a summary page accessing all of the California building codes see http://www.bsc.ca.gov/pubs/codeson.aspx
  • [34] "Guard Rail Height", CREIA, California Real Estate Inspection Association, Website: http://ask.creia.org, web search 8/1/12 original source: http://ask.creia.org/index.php?topic=424.0, December 2009
  • [35] California Department of Industrial Relations - CA/OSHA: California Stair & Railing Code details: Subchapter 7. General Industry Safety Orders, Group 1. General Physical Conditions and Structures Orders, Article 2. Standard Specifications, Section 3214. Stair Rails and Handrails, web search 8/1/12, original source: http://www.dir.ca.gov/title8/3214.html
  • [36] California Department of Industrial Relations - CA/OSHA: California Stair & Railing Code details: Subchapter 4. General Industry Safety Orders, Article 17. Ramps, Runways, Stairwells, and Stairs, Section 1626. Stairwells and Stairs., web search 8/1/12, original source: http://www.dir.ca.gov/title8/1626.html
  • [37] California Building Code, Nonstructural Design Requirements, web search 08/01/12 original source: http://sanbruno.ca.gov/comdev_images/California_Building_Code.pdf
  • ...

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.
  • Best Practices Guide to Residential Construction, by Steven Bliss. John Wiley & Sons, 2006. ISBN-10: 0471648361, ISBN-13: 978-0471648369, Hardcover: 320 pages, available from Amazon.com and also Wiley.com. See our book review of this publication.
  • Decks and Porches, the JLC Guide to, Best Practices for Outdoor Spaces, Steve Bliss (Editor), The Journal of Light Construction, Williston VT, 2010 ISBN 10: 1-928580-42-4, ISBN 13: 978-1-928580-42-3, available from Amazon.com
  • ...
HOME ABOUT CONTACT COPYING DESCRIPTION POLICIES PRINTING PRIVACY © 2013 Copyright InspectAPedia.com