What does mold look like under the microscope?

Organized alphabetically by mold name (mold genera/species), these mold spores and their photographs (both on site and under the microscope) have been collected in the U.S., Spain, Mexico, France, as well as in other countries. These are aerobiology laboratory photos of mold under the microscope.

We also provide a MASTER INDEX to this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need.

MOLD BY MICROSCOPE - What mold looks like under the light microscope

Aureobasidium pullulans (C) Daniel Friedman

In this article we provide lab photographs of mold under the microscope.

The photo at page top shows Aspergillus sp., fungal spores and condiophores under the microscope at 1200x.

Other photographs and articles at this website will help you find and recognize problematic toxic or allergenic mold in buildings.

Nearly all of our mold spore photographs shown at this mold spore identification assistance page are from field samples collected in buildings.

What makes these photographs helpful is that they are "real world" examples of mold spore occurrence, including the surrounding debris and sometimes rough growth patterns of mold spores that occur in situ in buildings.

Mold grown in the laboratory or on cultures is often very crisp, beautiful, and perhaps more easy to identify. But the actual physical structures of mold growth for a given genera and species may vary significantly depending on the material on which the mold is growing - its food. Photographs of mold spores under the microscope shown here are in that sense, more "natural" than those obtained from culture.

See MICROSCOPE DIGITAL PHOTOGRAPHY for advice on how to obtain and organize good photographs through the microscope.

Photographs of Mold Under the Microscope

Mold spore photographs are arranged alphabetically here. For example, if you are looking for what Stachybotrys chartarum spores and growth structures or conidiophores look like under the microscope, just scroll down to the "S" section of our identification photographs of mold under the microscope.

Index to Building Mold Genera/Species in This Document

A  -  B  -  C  -  D  -  E  -  F  -  G  -  H  -  I  -  J  -  K  -  L  -  M  -  N  -  O  -  P  -  Q -R  -  S  -  T  -  U  -  V  -  W  -  X  -  Y  -  Z

A

Acremonium-like Mold Spore Photographs

Acremonium mold photograph (C) Daniel Friedman

Here is a laboratory microscopic photograph of Acremonium like mold growth found on wet "fuzzy" basement vinyl flooring and at a water heater leak in Missouri.

Agrocybe mold spore under the microscope (C) Daniel Friedman

Agrocybe sp. mold spore photographs

Photograph of an Agrocybe spore (see Basidiomycetes). Individual Agrocybe spores are common in outdoor air samples collected with spore traps.

Alternaria sp. mold spore photographs

Alternaria mold spores - © 2017  - 2001  Daniel Friedman  Alternaria mold spores - © 2017  - 2001  Daniel Friedman

Alternaria mold spores in chain (C) Daniel Friedman

The photograph of Alternaria spores in a cluster (above left) shows these spores with their proper coloration. The Alternaria sp. photograph at above right demonstrates the confusion in spore coloration and thus in spore identification that can occur when a novice microscopist relies too heavily on fuchsin stains for spore detection.

Alternaria mold spores are very common in outdoor air and are likely to be found in outdoor air samples and are often found in indoor air samples as well. Growing on a building surface (or in culture) Alternaria sp. will also appear in spore chains (photo at left) and attached to fungal hyphae.

Our Alternaria sp. mold spore chain photo (left) also includes skin flakes and at bottom center an Ascomycete.

Comparing the Alternaria spores to the human skin cells and to the smaller Ascomycete you can see that Alternaria fungal spores are quite large among members of the Fifth Kingdom.

Arthrinium sp. mold spore photographs

Arthrinium fungal spores (in close-up at 1200x) form group of at least twenty species, some of which are ovate or lemon-shaped. Possible examples of A. phaeospermum are shown below. This fungus is often confused with the ubiquitous Chaetomium sp. fungal spore when the latter is not fully hydrated

. Look for not a fold in the spore (dessicated) but a hyaline band at the junction of the two sides, and look for the birth scar (bottom of the spore at below right) - that's an Arthrinium sp. spore not Chaetomium sp. [Thanks our instructors, mycologists Dr. Harriet Burge and Dr. John Haines.]

Chaetomium sp. is an Ascomycete, born in groups of 8, and without a birth scar as it emerges from a perethicium not by growing on a fungal hypha. And the center fold on Arthrinium will extend pretty much to the ends of the spore.

Aspergillis Structure - Daniel Friedman 05-02-00 Aspergillis Structure - Daniel Friedman 05-02-00

Aspergillus sp. mold spore photographs

Aspergillis Structure - Daniel Friedman 05-02-00 Aspergillis Structure - Daniel Friedman 05-02-00

Photographs of Aspergillus sp. mold spores under the microscope Aspergillus niger culture, Penicillium culture, Penicillium spores - Aspergillus and Penicillium spores are difficult to differentiate when they are found in air that you may see them reported in test results as "Pen/Asp".

Watch out: Most Pen/Asp spores are round, hyaline (colorless) and small and lack surface features to aid in their precise identification by microscope when the spores are found alone, or in air samples (and if not in spore chains).

In that case the spores may not even be identified as (potentially harmful) molds and may just be called "amerospores" in the lab report.

But when these spores appear in chains (as that's how they are born) they should not be labeled as "amerospores", and at least some of these airborne spores in the Aspergillus/Penicillium group can be identified from the spore alone, however, such as Aspergillus niger

Also see below our lab photograph of mold spores in this dense surface growth of Aspergillus niger and Aspergillus fumigatus side by side, in the same surface sample, but not quite intermixed.

Lab  photos of dense mold growth (C) Daniel Friedman

Below Aspergillus versicolor-like mold growing in culture and under the microscope; note that usually A. versicolor produces very long mold spore chains atop the conidiophore, not seen in these images.

Aspergillus in mold culture (C) Daniel Friedman Aspergillus versicolor-like mold under the microscope (C) Deniel Friedman

See MOLD APPEARANCE - WHAT MOLD LOOKS LIKE for images of what mold looks like when growing on building surfaces or materials.

Aspergillus penicilloides is not common in the indoor envrionment but may be detected. [Lab photo needed, use the page top or bottom CONTACT link] See this research citing Aspergillus penicilloides in the indoor environment (and the U.S. Space Station):

Aureobasidium pullulans fungal spore images

Aureobasidium pullulans (C) Daniel Friedman Aureobasidium pullulans (C) Daniel Friedman

We find lots of the fungus spores shown above, Aureobasidium pullulans, a black yeast fungus, growing on wet or damp wood in buildings, especially on plywood roof sheathing in poorly-vented building attics.

This yeast-like fungus is also often found on caulk or damp window frames in bathrooms. Aureobasidium may be pink or black in color. More detail is at MOLD ATLAS & PARTICLES INDEX. And we discuss this mold further at Recognize Harmless Black Mold.

B

Biolaris-Drechslera sp. mold spore photographs

Lab microscopic photographs of an Bipolaris-Drechslera spores are provided below. In lab reports Bipolaris sp. and Drechslera sp. fungal spores are often grouped together as a class because of physical similarity.

Bipolaris - Drechslera fungal spores © D Friedman at InspectApedia.com Bipolaris - Drechslera fungal spores © D Friedman at InspectApedia.com

C

Ceratocystis/Ophistoma - the Ophistomoid Cosmetic Black Sapstain or Bluestain Molds on Lumber

Ophistoma Ceratocystis sketch (C) Daniel Friedman Mycologia 1953 Ophistoma Ceratocystis sketch (C) Daniel Friedman Mycologia 1953

Laboratory microscopic photographs of Ceratocystis/Ophistoma type mold are a bit tricky in surface samples such as collected from moldy lumber, because usually this mold is dry, often encysted, and because it is not likely to be growing on an indoor surface, the sample may lack clear identifying particles or structures.

Here at above right we show a sketch of the perithecium, ascospores, and conidia of Endoconodiphora coerulescens from the July-August 1953 issue of Mycologia Vol XLV No. 4.

Our photograph at above left shows a fungus found under a basement stairwell that we classified as Ceratocystis/Ophistoma, and in this photograph you can see an enlarged closeup of mold fragments from that sample.

Watch out: Because this dark colored fungal growth appears "black" on wood surfaces, scaring some folks into unnecessary and costly "toxic black mold remediation" projects, we discuss the cosmetic Ceratocystis/Ophistoma mold group in detail at Recognize Harmless Black Mold.

Chaetomium sp. mold spore photographs

Lab microscopic photographs of an Chaetomium spores: Chaetomium sp. (C. globosum, C. aureum, and others) are very common indoor molds found especially where drywall or other paper covered products have been wet.

Chaetomium sp. (photo below left) is an Ascomycete and is ubiquitous in water damaged buildings, especially on drywall paper. We find Chaetomium fungal growth often co-existing with Stachybotrys sp./ S. chartarum (photo below right - the S. chartarum are the ovate black spores) Where Chaetomium mold growth has been found indoors in spore clusters like this it is probably appropriate to investigate the building leak history and to remain alert for the presence of other indoor mold reservoirs.

Chaetomium mold spore under the microscope (C) Daniel Friedman Chaetomium mold spore under the microscope (C) Daniel Friedman

Watch out: What Chaetomium fungal spores look like in the microscope depends a lot on how they are prepared (what mountant chemicals) and the extent of spore hydration. So Chaetomium that is not well hydrated remains "folded" to produce a center furrow that can cause it to be mistaken for Arthrinium sp. (a mistake we see in Grant Smith's execllent book of mold photos) and other molds.

Our Chaetomiium sp. photo at below left illustrates both hydrated and under-hydrated spores. At below right we see a close-up of a few Chaetomium spores at 1200x via our Polam microscope.

Chaetomium mold spore under the microscope (C) Daniel Friedmana Chaetomium mold spore under the microscope (C) Daniel Friedman

Below: Chaetomium globosum under the microscope. Warning: when dessicated these spores can fold inwards to produce a false scar.

Chaetomium globosum spores (C) Daniel Friedman Chaetomium globosum spores (C) Daniel Friedman

Cladosporium sp. mold spore photographs

Cladosporium mold spores  © Daniel Friedman 2001 Cladosporium sphaerospermum (C) Daniel Friedman
Cladosporium mold spores  © Daniel Friedman 2001

Microscope photographs of Cladosporium sp.: Cladosporium sp. are the most common mold spore found in outdoor air in many areas, so common in fact that Cladosporium is called "the king of molds". The photograph of Cladosporium sp. spores in a cluster (above left) shows these spores with their proper coloration.

The Cladosporium sp. photograph at above right demonstrates the confusion in spore coloration and thus in spore identification that can occur when a novice microscopist relies too heavily on fuchsin stains for spore detection. However both photographs show the characteristic dark scars at the attachment point for these mold spores.

Our photograph at left shows the dominant spherical spores produced by Cladosporium sphaerospermum - another common indoor and attic/roof-sheathing mold.

Curvularia sp. mold spore photographs

Curvularia mold spores  © Daniel Friedman 2001 Curvularia mold spores  © Daniel Friedman 2001

Curvularia mold spores at above left may not be looking their best in this field photo but this is what you're likely to see at the microscope. The Curvularia sp. at above right was in better condition, showing its attachment scar as well.

D

Drechslera sp. mold spore photographs

Ganoderma basidiospores  © Daniel Friedman 2001

Microscope photographs of Drechslera sp. fungal spores - under the microscope Drechslera and Bipolaris mold spores are both large, segmented spores such as the member shown here, and may require additional careful examination to differentiate the two.

E

Epicoccum sp. mold spore photographs

Epicoccum niger mold spore photograph  © Daniel Friedman 2001

Microscope photographs of Epicoccum sp. (E. niger)fungal spores under the microscope are large, segmented spores such as the member shown here.

F

Fuglio septica mold & mold spore spore photographs - "Dog vomit" mold.

Fuglio septic mold and mold spores photographs © Daniel Friedman 2001 Fuglio septic mold and mold spores photographs © Daniel Friedman 2001

Fuglio septica is shown under the stereoscopic microscope (less than 100x) at above left, while Fuglio septica mold spores are shown at above right. This fungus is affectionately called "dog vomit mold" by some field investigators as when found growing outdoors on bark chips that's about what it looks like. We do not normally find this mold growing indoors.

G

Ganoderma sp. mold spore photographs

Ganoderma basidiospores  © Daniel Friedman 2001

Microscope photographs of Ganoderma basidiospores such as G. applanatum & G. tsuge dominated the air at a recent fungal spore study workshop sponsored by the University of Montreal. Here is where they were coming from.

Gonadobotryum mold spore microphotographs

Ganoderma basidiospores  © Daniel Friedman 2001

Here are microscopoic photographs of Gonadobotryum sp. mold collected during a building investigation. We often find Gonadobotryum sp. mold growth present as a parasite, growing on top of other fungi, especially in the Ceratocystis/Ophistoma group on framing lumber.

The presence of Gonadobotryum sp. mold on framing lumber is probably not a health concern; it has not been reported as producing mycotoxins but we would not rule out its possible role as an allergen.

HIJKL

M

Meruliporia Incrassata - "Poria" "House Eating Fungus" Mold Microphotographs

Meruliporia incrassata mold photo (C) Daniel Friedman

Here are microscopoic photographs of Meruliporia incrassata mold spores collected in a building where extensive structural rot was found and "yellow mold" was visible on some of the rotting lumber.

We discuss this fungus in more detail at Meruliporia Mold Photographs.

N

Nigrospora sp. mold spore photographs

Nigrospora sp. © Daniel Friedman 2001

Nigrospora sp. mold spores are often round, smooth, and black under the microscope.

It is useful to check out black round "spores" under the microscope using top lighting in order to distinguish them from paint droplets where paint has been sprayed in the building. If the round spherical objects are all smooth but their size varies, or if toplighting shows that the "spores" are white or some other color, you're probably looking at spray paint droplets, not Nigrospora sp. mold spores.

O

Oidium (Mildew) sp. mold spore photographs

Oidium sp. mildew spores © Daniel Friedman 2001

Oidium sp. is one of the most common appearances of the sub-group of molds in the mildew family.

This mold is often found in outdoor air. We do not normally find mildew growing on any indoor surface in buildings because the mildews are obligate parasites - growing only on living plants.

These spores are easy to identify by their color (none or hyaline), and their shape as well as their cellular inclusions or surface decorations visible in any sharply focused microscope at 400x or higher.

P

Penicillium sp. mold spore photographs

Photographs of spores of Penicillium sp. © Daniel Friedman 2001

Penicillium sp. mold spores are very easy to identify when their spore producing conidiophores are collected in a surface sample (photograph at left).

But individual Penicillium sp. spores found in air or dust samples are difficult to distinguish (visually) from many Aspergillus spores as well as some other genera/species including some mold spores from a very different group, the Basidiomycetes.

A lab report of the presence of Amerospores (a generic name for unidentified small round colorless un featured spores) should not be assumed to have detected Penicillium sp.

Periconia sp. mold spore photographs

Photographs of spores of Periconia sp. © Daniel Friedman 2001

Periconia sp. mold spores are common at low levels in both indoor and outdoor air and dust samples.

Phoma sp. mold spore photographs

Phoma sp. mold spores are sometimes found indoors on building surfaces where leaks and rot damage are present.

Photographs of spores of Phoma sp. © Daniel Friedman 2001

Puffball mold spore photographs

Photographs of spores of puffball spores © Daniel Friedman 2001

Puffball mold spores (Basidiomycetes) are common in outdoor air samples in some seasons.

The spores are easily distinguished by their little hyphal stem attachments making them look a lot like tiny balloons.

If you ever stomped on those brown dried fungal clumps (when you were a kid), sending clouds of brown dust into the air, these photos show what you were sending aloft.

Native americans used puffball spores for medicinal purposes as well, possibly as a clotting agent on wounds.

Q

...

R

Rhizopus fungal spore & spore structure photographs - Rhizopus oryzae sporangium

Rhizopus sporangium and Rhizopus oryzae fungal spores (C) Daniel Friedman

At lower-left in the Rhizopus photograph above is (apparently) a dust mite fecal pellet comprised of fungal spores - Ed.

S

Smut spore photographs

Photographs of spores of smut spores © Daniel Friedman 2001

Smut spores common in outdoor air samples, would be unusual indoors.

Sporomiella fungal spores (Ascomycetes)

Sporomiella, an ascomycete (C) Daniel Friedman

Stachybotrys sp. / Stachybotrys chartarum black mold spore photographs

Stachybotrys mold and mold spore photographs - Daniel Friedman 05-02-00 Stachybotrys mold and mold spore photographs - Daniel Friedman 05-02-00
Stachybotrys Structure - Daniel Friedman 05-02-00

Stachybotrys sp. "black mold" spore photographs under the microscope as well as on building surfaces are provided here.

Stachybotrys chartarum mold contamination on a wall, [image]

Stachybotrys mold structure,

Stachybotrys spores (with basidiospores (?),

Stachybotrys mold in culture has been identified (and then later questioned) as a cause of and pulmonary hemorrhage and hemosiderosis in infants. (http://gcrc.meds.cwru.edu/stachy/default.htm) While this mold has received recent media attention, many molds occur naturally outdoors and indoors.

Some other more common mold spores such as Penicillium and Aspergillus (see above) may cause illness or may be associated or aggravate with some types of asthma. Stachybotrys mold, in another form, MEMNONIELLA ECHINATA we've found to be particularly reactive even in small quantities. When found on building surfaces it should be removed.

Stemonitis mold & mold spore photographs

Photographs of spores of stemonitis mold and spores © Daniel Friedman 2001 Photographs of spores of stemonitis mold and spores © Daniel Friedman 2001

Stemonitis mold & photographs of stemonitis mold spores common growing indoors on wet oriented strand board.

T

Torula sp. mold spore micro-photographs

Photographs of spores of Torula mold © Daniel Friedman 2001

 

Torula sp. fungal spores are shown in this lab photograph taken through the microscope, probably Torula herbarum.

We often encounter this mold on wet moldy or rotted plywood subfloors in buildings.

U

Ulocladium mold spore micro-photographs

Ulocladium sp. is often confused with similar looking versions of Stemphylium sp. and with some species of Alternaria sp. particularly as immature Alternaria spores can look like the simpler ovate cross-septated Ulocladium chartarum. And worse there are species of Ulocladium (U. alternariae - cf Ellis) that look like (and are even named after Altenaria sp.).

The differentiation between species of Alternaria and Ulocladium is not difficult once you've been instructed by a mycologist. The "tail" you see on the Alternaria-like mold spores still attached to hyphae (photo below right) comprises the attachment point for the spore to its hyphae. The "tail" on an Alternaria spore is at the opposite end of the mold from its attachment.

That is, an Alternaria spore is attached to its hyphae at its larger "head" end, not by its tail.

Ulocladium chartarum (below-left). Ulocladium sp. (below right).

Ulocladium chartarum mold spores © D Friedman at InspectApedia.com Uocladium-like mold spores - Daniel Friedman 08-17-01

Below are microphotographs of U. chartarum grown in culture by the author [DF].

Ulocladium chartarum mold spores © D Friedman at InspectApedia.com Uocladium-like mold spores - Daniel Friedman 08-17-01

We have almost 900,000 photomicrographs of mold spores and pollen grains - more are coming to this website. If you need to see a specific image, contact us. Content Use / Reproduction Policy - it's OK to reproduce web articles in non-commercial-use printed form only, do not make electronic copies.

MAKING ELECTRONIC COPIES OF our WEBSITE CONTENTS (such as copying our pages, content from our pages, or our graphics to another website or into email) IS EXPRESSLY PROHIBITED - this website is © protected material, all rights reserved.

V

Verticillium sp. or Verticillium-like mold spore hyphae and spore photographs

Verticillium like fungal spores and hyphae (C) Daniel Friedman Verticillium like fungal spores and hyphae (C) Daniel Friedman

W

Wallemia serbi or Wallemia-like fungal spore photographs

Wallemia serbi-like fungal spores & spore chains (C) Daniel Friedman

 

XY

 

Z

Zygophiala jamaicensis -like fungal spore photographs

Zygophiala jamaicensis -like fungal spore photographs of this spore in a dust sample (C) Daniel Friedman

Directories of 6 atlases or indices of building mold

Articles on What Mold Looks Like

...


Continue reading at MOLD in the PETRI DISH, PHOTOS or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Or see FORENSIC & IAQ LAB MICROSCOPE TECHNIQUES

Or see MICROSCOPE DIGITAL PHOTOGRAPHY for advice on how to obtain and organize good photographs through the microscope

Or see POLLEN_PHOTOS

Suggested citation for this web page

MOLD by MICROSCOPE at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to MOLD CONTAMINATION & REMEDIATION

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs

Ask a Question or Search InspectApedia

Questions & answers or comments about what building mold looks at under the light microscope at magnifications from 10x to 1200x. .

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.