Typar house wrap example (C) Daniel FriedmanTyvek™ Installation at Building Sills, Soles, Top Plates

  • HOUSEWRAP at SILLS, SOLES, TOP PLATES - CONTENTS: Air seal strategies using Tyvek™ and similar housewrap products to save building energy costs for heating or cooling. Estimates of before and after building air leaks and air changes per hour for older homes. Estimates of cost savings from sealing air leaks. Other indoor air quality problems that may occur when air leaks are sealed. Table shows relative importance of various building air leaks. Solar Age Magazine Articles on Renewable Energy, Energy Savings, Construction Practices
  • POST a QUESTION or READ FAQs about best details for installing housewrap at building sills, soles, and top plates
  • REFERENCES
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Housewrap or sheathing wrap (such as Tyvek™) installation details:

Here using a Q&A format we discuss basic concepts & strategies for installing/using Tyvek™ air barrier on buildings and sealing against air leaks. Here we include solar energy, solar heating, solar hot water, and related building energy efficiency improvement articles including material reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss. Our page-top photo shows Typar™ house wrap during installation on a new home.



Green links show where you are. © Copyright 2017 InspectApedia.com, All Rights Reserved.

Advice for Installing Tyvek™ Housewrap on buildings

Housewrap installation (C) D Friedman

The question-and-answer article about strategies for sealing air infiltration leaks on buildings (or air exfiltration leaks, i.e. heat loss), is provided in full-text below, and discusses steps to take to be sure that the energy retrofit cure is not worse than the disease, quotes-from, updates, and comments an original article from Solar Age Magazine and written by Steven Bliss.

Should I Install Tyvek at Sill, Sole, & Top Plates & Do I need to Caulk

Housewrap installation (C) D Friedman

Question:

If a continuous air/vapor barrier is used on the interior of the framing of a house, and DuPont Tyvek™ is used on the outside, is it necessary to caulk at sill, sole, and top plates, headers, and joists? -- John L. Matthews

Answer:

In tests conducted by the NAHB Research Foundation, a standard 1976 house - 2x4 walls, kraft-paper vapor barrier, asphalt-impregnated sheathing - had a 35-percent reduction in air leakage under pressure after being retrofitted with Tyvek™.

The Tyvek was lapped at seams and caulked at windows and foundation. The reduction in air leakage was from 8.6 to 5.6 air changes per hour (ACH) at 50 Pascals (of pressure).

Ten air changes per hour (ACH) at 50 Pascals equals roughly 0.5 natural ACH in a building.

According to NAHB researchers, later tests on tighter homes showed smaller reductions, but even "quick and dirty" installations of Tyvek showed some reduction in air leakage rates. In a test by Gulf State Utilities of Beaumont, Texas, Tyvek did about the same as caulking with expanding polyurethane foam insulation, but both together did significantly better than either alone.

DuPont recommends that Tyvek be lapped at seams and caulked at the foundation. It is also advisable to lap the Tyvek over the top plate and caulk around windows.

If these Tyvek installation guidelines are followed (for this and presumably most other Housewrap brands), we suspect that you could be less finicky with other sealing efforts. Many builders, though, appreciate the redundancy of an extra line of air leak defense won at a modest cost through the use of this product.

Names of compatible adhesives and other information about Tyvek are available from DuPont at 800-448-9835.

Original Article

The link to the original Q&A article in PDF form immediately below was preceded by an expanded/updated online version of this article.

Water Barrier & House Wrap Articles

...


Continue reading at VAPOR BARRIERS & AIR SEALING BAND JOISTS or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Or see VAPOR BARRIERS & CONDENSATION in BUILDINGS

Suggested citation for this web page

HOUSEWRAP at SILLS, SOLES, TOP PLATES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to EXTERIORS of BUILDINGS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs

Ask a Question or Search InspectApedia

Questions & answers or comments about best details for installing housewrap at building sills, soles, and top plates.

Use the "Click to Show or Hide FAQs" link just above to see recently-posted questions, comments, replies, try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.