  • FIBERGLASS DUCT, RIGID CONSTRUCTION - CONTENTS: Rigid insulating board to build air conditioning or heating ducts. Tools used to construct ductwork. How to use fiberglass duct board to construct HVAC ductwork. Use of rigid duct board with a thermosiphoning air collector (TAP). Using basement air with a thermo-siphoning air collector system. Solar Age Magazine Articles on Renewable Energy, Energy Savings, Construction Practices
  • POST a QUESTION or READ FAQs about rigid fiberglass duct insulation board
  • REFERENCES
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Fiberglass insulating duct board:

This article discusses the use of rigid insulating board to construct air conditioning and heating system ductwork, and use of rigid ductwork with a thermosiphoning air collector system (TAP).



Green links show where you are. © Copyright 2017 InspectApedia.com, All Rights Reserved.

Rigid Insulating Board & Fiberglass Air Conditioning & Heating Duct Construction

Exposed fiberglass in ductwork (C) Daniel Friedman

[Click to enlarge any image]

Our page top photograph shows reinforced aluminum foil faced fiberglass duct board used to construct the supply air plenum on a heating system.

The question-and-answer article below paraphrases, quotes-from, updates, and comments an original article from Solar Age Magazine and written by Steven Bliss.

Question: How are Rigid-Insulation Ducts Constructed, What Materials & Tools are Used?

I have heard that rigid insulating board can be used to construct heating ducts (or air conditioning ductwork). Can you provide information about the construction of rigid insulating board ductwork, including duct construction tools, etc.?

Is it reasonable to use rigid duct board with a thermosiphoning air collector (TAP), considering that I desire to move air 12 to 15 feet from the south wall to the middle of a one-story house?

This thermosiphoning air collector plan also includes using air from the basement to enter the cold side of the TAP. -- Byrl Bowman, Kalamazoo, MI

Answer: Fiberglass Duct Board

The product you refer to is fiberglass duct board, available from Certainteed, Knauf, and Owens Corning.

The fiberglass insulating board panels are one-inch in thickness, R-4.3, rigid-fiberglass panels that have a reinforced kraft paper or foil facing on one side. Rigid fiberglass duct board panels can be cut and fitted on site using a utility knife and special grooving tools to make the folds and laps.

The duct board sections are stapled together and sealed using pressure-sensitive aluminum foil tape.

The duct construction hand tools are made by AmCraft, Inc..

To purchase fiberglass insulation duct board materials, check with the larger heating and air-conditioning supply houses in your area, or with a manufacturer's rep.

As for your plan to use a thermosiphoning air collector, it sounds fine, but don't expect much air flow from a thermosiphoning collector if the system is ducted. A fan will be needed.

Technical Opinion About Rigid Fiberglass Ductwork

Foil faced rigid fiberglass duct board has proven an excellent system for constructing air plenums and main trunk lines for duct systems for both heating and air conditioning, and is in popular use across North America as well as in other countries. -- DJ Friedman

Advantages of Rigid Fiberglass Duct Board

Disadvantages of Rigid Fiberglass Duct Board

Exposed fiberglass in ductwork (C) Daniel Friedman

Here we include solar energy, solar heating, solar hot water, and related building energy efficiency improvement articles reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss.

Original Article

The link to the original Q&A article in PDF form immediately below is preceded by an expanded/updated online version of this article.

...


Continue reading at FIBERGLASS ENVIRO-SCARE or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Or see ASBESTOS PAPER DUCT INSULATION

Or see DUCT SYSTEM & DUCT DEFECTS - home

Or see FIBERGLASS INSULATIONand HVAC duct work insulation hazards

Or see WHY DOES MOLD GROW in INSULATION?

Suggested citation for this web page

FIBERGLASS DUCT, RIGID CONSTRUCTION at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to ARTICLE INDEX to HVAC DUCT SYSTEMS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs

Ask a Question or Search InspectApedia

Questions & answers or comments about possible sources of small fiberglass fragments found in indoor air & dust samples.

Use the "Click to Show or Hide FAQs" link just above to see recently-posted questions, comments, replies, try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.