InspectAPedia.com InspectAPedia®
Google
InspectAPedia
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • DAMAGE ASSESSMENT
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



InspectAPedia ® Home

ROOFING INSPECTION & REPAIR

ALUMINUM ROOFING
AMERICAN CEMWOOD ROOFING
ARCHITECTURE & BUILDING COMPONENT ID
ASBESTOS IDENTIFICATION IN buildings
ASBESTOS CEMENT ROOFING
ASBESTOS MATERIAL REGULATIONS
ASBESTOS REGULATION Update
ASPHALT ROOF SHINGLES
ATTIC LEAKS, CONDENSATION & MOLD
ATTIC VENTILATION

BEST ROOFING PRACTICES
BUILDING SAFETY HAZARDS GUIDE
BUILT UP ROOFS

CEMWOOD ROOFING
CERTIFICATIONS for ROOFING CONTRACTORS
CHIMNEY INSPECTION & REPAIRS
CHOOSING A ROOFING CONTRACTOR
CLAY TILE ROOFING
COLD WEATHER ROOF TROUBLE

CONCRETE ROOFING
CORRUGATED ROOFING
COPPER ROOFING
DEBRIS STAINING on ROOFS

DECKS, ROOFTOP CONSTRUCTION
DEFINITIONS of ENGINEERED WOOD OSB LVL etc
DISASTERS: BUILDING INSPECTION & REPAIR

EARLY ROOF FAILURE DIAGNOSTIC QUESTIONS
EARLY ROOF FAILURE DIAGNOSTIC QUESTIONS
EPDM ROOFS
EXTRACTIVE BLEEDING on SHINGLES

FELT UNDERLAYMENT REQUIREMENTS
FIBER CEMENT & FIBERBOARD ROOFING
FIRE RATINGS for ROOF SURFACES
FIRE RETARDANT PLYWOOD
FLASHING on BUILDINGS
FLASHING, ASPHALT SHINGLE VALLEYS
FLASHING, CHIMNEY Mistakes & Leaks
FLASHING, CLAY TILE ROOFS
FLASHING MEMBRANES PEEL & STICK
FLASHING for METAL ROOFS
FLASHING ROOF WALL DETAILS
FLASHING ROOF-WALL SNAFU
FLASHING SIDING DETAILS
FLASHING WALL DETAILS
FLASHING WINDOW DETAILS
FLASHING WOOD ROOF DETAILS
FLAT ROOF MOISTURE & CONDENSATION

GUTTERS & DOWNSPOUTS

HEAT TAPES & CABLES on Roofs for Ice Dams

ICE DAM PREVENTION
INSECT INFESTATION / DAMAGE
INSULATION IDENTIFICATION GUIDE
INSULATION INSPECTION & IMPROVEMENT

LEAD POISONING HAZARDS GUIDE
LEAKY ROOF DIAGNOSIS & REPAIR
LEED GREEN BUILDING CERTIFICATION
LOW SLOPE ROOFING

MASONITE WOODRUF FIBERBOARD ROOFING
MEMBRANE & SINGLE PLY ROOFS
METAL ROOFING
MODIFIED BITUMEN ROOFING

NOISE / SOUND DIAGNOSIS & CURE
NOISE CONTROL for ROOFS

PLASTIC ROOFING TYPES

ROLL ROOFING, ASPHALT
ROOF ARCHITECTURAL STYLES - PHOTO GUIDE
ROOF CLEANING RECOMMENDATIONS
ROOF COLOR RECOMMENDATIONS
ROOF DORMER TYPES - PHOTO GUIDE
ROOF INSPECTION SAFETY & LIMITS
ROOF JOB PROBLEMS, RESOLVING
ROOF LEAK DIAGNOSIS & REPAIR
ROOF NOISE TRANSMISSION
ROOF REPLACEMENT SNAFUs
ROOF SLOPE DEFINITIONS
ROOF VENTILATION SPECIFICATIONS
ROOFING FELT UNDERLAYMENT REQUIREMENTS
ROOFING MATERIALS, Age, Types
ROOFING TILE SHAPES & PROFILES
ROOFING UNDERLAYMENT BEST PRACTICES

SADDLE CONSTRUCTION at CHIMNEYS
SLATE ROOF INSPECTION & REPAIR
SNOW GUARDS & SNOW BRAKES
SOD ROOFING
SOUND CONTROL in buildings
STAINS on & in BUILDINGS, CAUSES & CURES
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAIN DIAGNOSIS on ROOFS
STAIN DIAGNOSIS on STONE
STANDARDS for ROOFING
STONE CLEANING METHODS
STONE ROOFING
STRESS SKIN INSULATED PANELS

TEST LABS - ROOF SHINGLE
THATCH ROOFING
Thermal Expansion Cracking of Brick
THERMAL EXPANSION of HOT WATER
THERMAL EXPANSION of MATERIALS
THERMAL IMAGING, THERMOGRAPHY
THERMAL IMAGING MOLD SCANS
THERMAL MASS in BUILDINGS
TILE ROOFING
TREES & SHRUBS, TRIM OFF BUILDING
TRUSS UPLIFT, ROOF
TRUSSES, Floor & Roof

UNDERLAYMENT REQUIREMENTS on ROOFS

VENTILATION in BUILDINGS

WALK-ON ROOF SURFACES
WARRANTIES for ROOF SHINGLES
WALL CONSTRUCTION BARRIER vs CAVITY
WATER ENTRY in buildings
WIND DAMAGE to ROOFS
WINTERIZE A BUILDING
WOOD SHAKE & SHINGLE ROOFING
WORKMANSHIP & ROOF DAMAGE

ZINC METAL ROOFING

More Information

EPDM or membrane roof (C) Daniel Friedman Walk-On or "Walkable
Roofing Types, Product Sources, Installation, Defects, Repairs
     

  • Membrane roof materials
    • Definition of Membrane roofing
    • Types of Membrane roofs
    • EPDM roofs, Rubber Roofs, Modified Bitumen Roofs
  • Questions & answers about how to construct a walkable or walk-on roof; walkable roof installation, troubleshooting, repair, decks-over
  • References

Click to Show or Hide Related Topics

  • x - home page
  • ROOFING INSPECTION & REPAIR - home
  • AGE OF ROOFING
  • ASBESTOS CEMENT & FIBER CEMENT ROOFS
  • ASPHALT ROOF SHINGLES
  • BEST ROOFING PRACTICES
  • BUILT UP ROOFS
  • CHOOSING A ROOFING CONTRACTOR
  • CLAY TILE ROOFING
  • CONCRETE ROOFING
  • CORRUGATED ROOFING
  • COPPER ROOFING
  • DEBRIS STAINING on ROOFS
  • EPDM, RUBBER, PVC ROOFING
  • EXTRACTIVE BLEEDING on SHINGLES
  • FELT UNDERLAYMENT REQUIREMENTS
  • FIBER CEMENT & FIBERBOARD ROOFING
  • FIRE RATINGS for ROOF SURFACES
  • FLASHING on BUILDINGS
  • HAIL DAMAGED SHINGLES
  • HOT ROOF DESIGNS: Un-Vented Roofs
  • ICE DAM PREVENTION
  • LEAKY ROOF DIAGNOSIS & REPAIR
  • LOW SLOPE ROOFING
  • MEMBRANE & SINGLE PLY ROOFS
  • METAL ROOFING
  • MODIFIED BITUMEN ROOFING
  • PLASTIC ROOFING TYPES
  • PVC, EPDM ROOFING
  • ROLL ROOFING, ASPHALT
  • ROOF SLOPE DEFINITIONS
  • ROOF VENTILATION SPECIFICATIONS
  • RUBBER ROOFING
  • SLATE ROOF INSPECTION & REPAIR
  • SOD ROOFING
  • STAIN DIAGNOSIS on ROOFS
  • STONE ROOFING
  • THATCH ROOFING
  • TILE ROOFING
  • UNDERLAYMENT REQUIREMENTS, ROOF
  • WIND DAMAGE to ROOFS
  • WOOD SHAKE & SHINGLE ROOFING
  • ZINC METAL ROOFING
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

This article describes sources and types of walk-on roof surface roofing materials, systems, installation suggestions, and product sources.

Also see DECKS, ROOFTOP CONSTRUCTION.

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

Walkable Roof Surfaces - Design, Product Sources, Installation

(Contributions, critique, corrections are invited: CONTACT us.)

Carson Dunlop's illustrations (below) compare an EPDM roof membrane installation and a PVC roof membrane installation.

Roll Roofing Problems (C) Carson Dunlop AssociatesRoll Roofing Problems (C) Carson Dunlop Associates

Materials & Installation Advice for Walkable Roofing Membranes

As explained in Best Practices Guide to Residential Construction, chapter on BEST ROOFING PRACTICES:

For rooftops that will also serve as decks (see “Rooftop Decks,” [online version coming] page 150 in the printed text Best Practices Guide to Residential Construction), one option is to use a roofing material designed for foot traffic.

Duradek (Duradek U.S. Inc.) is a sheet vinyl membrane similar to Hypalon but with a nonskid wear surface. It was developed over 25 years ago for waterproofing decks, balconies, and outdoor living spaces. For use over a living space, the manufacturer recommends its 60-mil Ultra series, which is warranted against leakage for 10 years.

Duradek is made of reinforced PVC sheet with heat stabilizers and additives for resistance to fire, UV degradation, and mildew. The wear surface is textured for slip resistance and available in a variety of colors.

Installation Tips for Walk-On Roofs

Installation is similar to other single plies and must be done by factory-certified contractors. The membrane glues to almost any clean substrate with either a proprietary contact cement or a special water-based adhesive applied with a notched trowel. Seams are heat welded with a heat gun, the most critical step. Like other single-ply membranes, the material is self-flashing at abutting walls and penetrations.

Pros and Cons of Duradek Walkable Roofing Membranes

Duradek creates an attractive and durable no-skid deck surface that can withstand normal wear and tear, direct sun exposure, high winds, and freeze-thaw cycles. However, because the membrane is also the wear surface, it can be damaged by cigarette burns, punctures, and heavy abrasion.

-- Adapted with permission from Best Practices Guide to Residential Construction.


Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Use the search box below to ask a question or to search the InspectApedia.com website.

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. Mr. Cramer serves on the ASHI Home Inspection Standards. Contact Mark Cramer at: 727-595-4211 mark@BestTampaInspector.com
  • John Cranor is an ASHI member and a home inspector (The House Whisperer) is located in Glen Allen, VA 23060. He is also a contributor to InspectApedia.com in several technical areas such as plumbing and appliances (dryer vents). Contact Mr. Cranor at 804-747-7747 or by Email: johncranor@verizon.net
  • Carson, Dunlop &
Associates Ltd., TorontoCarson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. (416) 964-9415 1-800-268-7070 info@carsondunlop.com. The firm provides professional home inspection services & home inspection education & publications. Alan Carson is a past president of ASHI, the American Society of Home Inspectors. Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home. Carson Dunlop Associates' provides:
    • Commercial Building Inspection Courses - protocol ASTM Standard E 2018-08 for Property Condition Assessments
    • Home Inspection Education Courses including home study & live classes at eleven colleges & universities.
    • Home Inspection Education Home Study Courses - ASHI@Home Training 10-course program.
      Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on these courses: Enter INSPECTAHITP in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
    • The Home Reference Book, a reference & inspection report product for building owners & inspectors.
      Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
    • The Home Reference eBook, an electronic version for PCs, the iPad, iPhone, & Android smart phones.
      Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter inspectaehrb in the order payment page "Promo/Redemption" space.
    • The Illustrated Home illustrates construction details and building components, a reference for owners & inspectors.
      Special Offer: For a 5% discount on any number of copies of the Illustrated Home purchased as a single order Enter INSPECTAILL in the order payment page "Promo/Redemption" space.
    • The Horizon Software System manages business operations,scheduling, & inspection report writing using Carson Dunlop's knowledge base & color images. The Horizon system runs on always-available cloud-based software for office computers, laptops, tablets, iPad, Android, & other smartphones.
  • "Choosing Roofing," Jefferson Kolle, January 1995, No. 92, Fine Homebuilding, Taunton Press, 63 S. Main St., PO Box 5506, Newton CT 06470 - 800-888-8286 - see http://www.taunton.com/FineHomebuilding/ for the magazine's website and for subscription information.
  • Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF] ISBN-10: 0471331724 ISBN-13: 978-0471331728
  • Building Pathology: Principles and Practice, David Watt, Wiley-Blackwell; 2 edition (March 7, 2008) ISBN-10: 1405161035 ISBN-13: 978-1405161039
  • Historic Preservation Technology: A Primer, Robert A. Young, Wiley (March 21, 2008) ISBN-10: 0471788368 ISBN-13: 978-0471788362
  • Problems in Roofing Design, B. Harrison McCampbell, Butterworth Heineman, 1991 ISBN 0-7506-9162-X (available used)

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.
  • Best Practices Guide to Residential Construction, by Steven Bliss. John Wiley & Sons, 2006. ISBN-10: 0471648361, ISBN-13: 978-0471648369, Hardcover: 320 pages, available from Amazon.com and also Wiley.com. See our book review of this publication.
  • Decks and Porches, the JLC Guide to, Best Practices for Outdoor Spaces, Steve Bliss (Editor), The Journal of Light Construction, Williston VT, 2010 ISBN 10: 1-928580-42-4, ISBN 13: 978-1-928580-42-3, available from Amazon.com
  • The Journal of Light Construction has generously given reprint permission to InspectAPedia.com for this article. All rights and contents are ©Journal of Light Construction and may not be reproduced in any form.
  • Asphalt Roofing Residential Manual,
  • Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF] ISBN-10: 0471331724 ISBN-13: 978-0471331728
  • Building Pathology: Principles and Practice, David Watt, Wiley-Blackwell; 2 edition (March 7, 2008) ISBN-10: 1405161035 ISBN-13: 978-1405161039
  • Concrete Folded Plate Roofs, C. Wilby PhD BSc CEng FICE FIStructE (Author), Butterworth-Heinemann, 1998, ISBN-10: 0340662662, ISBN-13: 978-0340662663
  • Concrete Shell Roofs, C. Wilby PhD BSc CEng FICE FIStructE (Author),
  • Concrete Dome Roofs (Longman Concrete Design and Construction Series),
  • Green Roof Plants: A Resource and Planting Guide, Edmund C. Snodgrass, Lucie L. Snodgrass, Timber Press, Incorporated, 2006, ISBN-10: 0881927872, ISBN-13: 978-0881927870. The text covers moisture needs, heat tolerance, hardiness, bloom color, foliage characteristics, and height of 350 species and cultivars.
  • Green Roof Construction and Maintenance, Kelley Luckett, McGraw-Hill Professional, 2009, ISBN-10: 007160880X, ISBN-13: 978-0071608800, quoting: Key questions to ask at each stage of the green building process Tested tips and techniques for successful structural design Construction methods for new and existing buildings Information on insulation, drainage, detailing, irrigation, and plant selection Details on optimal soil formulation Illustrations featuring various stages of construction Best practices for green roof maintenance A survey of environmental benefits, including evapo-transpiration, storm-water management, habitat restoration, and improvement of air quality Tips on the LEED design and certification process Considerations for assessing return on investment Color photographs of successfully installed green roofs Useful checklists, tables, and charts
  • Handbook of Building Crafts in Conservation, Jack Bower, Ed., Van Nostrand Reinhold Company, NY 1981 ISBN 0-442-2135-3 Library of Congress Catalog Card Nr. 81-50643.
  • Historic Preservation Technology: A Primer, Robert A. Young, Wiley (March 21, 2008) ISBN-10: 0471788368 ISBN-13: 978-0471788362
  • Historic Slate Roofs : With How-to Info and Specifications, Tina Skinner (Ed), Schiffer Publishing, 2008, ISBN-10: 0764330012 , ISBN-13: 978-0764330018
  • Low Slope Roofing, Manual of, 4th Ed., C.W. Griffin, Richard Fricklas, McGraw-Hill Professional; 4 edition, 2006, ISBN-10: 007145828X, ISBN-13: 978-0071458283
    • Roof failure causes in depth (and specific methods for avoiding them)
    • Roof design fundamentals and flourishes, based on voluminous industry research and experience
    • New technologies and materials -- using them safely and correctly
    • Comprehensive coverage of all major roofing systems pecifications, inspection, and maintenance tools for roofing work
  • Problems in Roofing Design, B. Harrison McCampbell, Butterworth Heineman, 1991 ISBN 0-7506-9162-X (available used)
  • Roofing The Right Way, Steven Bolt, McGraw-Hill Professional; 3rd Ed (1996), ISBN-10: 0070066507, ISBN-13: 978-0070066502
  • Slate Roofs, National Slate Association, 1926, reprinted 1977 by Vermont Structural Slate Co., Inc., Fair Haven, VT 05743, 802-265-4933/34. (We recommend this book if you can find it. It has gone in and out of print on occasion.)
  • The Slate Roof Bible, Joseph Jenkins, www.jenkinsslate.com, 143 Forest Lane, PO Box 607, Grove City, PA 16127 - 866-641-7141 (We recommend this book).
  • Slate Roofing in Canada (Studi4es in archaeology, architecture, and history),
  • Smart Guide: Roofing: Step-by-Step Projects, Creative Homeowner (Ed), 2004, ISBN-10: 1580111491, ISBN-13: 978-1580111492
  • Tile Roofs of Alfred: A Clay Tradition in Alfred NY
  • "Weather-Resistive Barriers [copy on file as /interiors/Weather_Resistant_Barriers_DOE.pdf ] - ", how to select and install housewrap and other types of weather resistive barriers, U.S. DOE
  • Wood Shingle Roofs, Care and Maintenance of wood shingle and shake roofs (EC), Stanley S. Niemiec (out of print)
  • ...

HOME ABOUT CONTACT COPYING DESCRIPTION POLICIES PRINTING PRIVACY © 2013 Copyright InspectAPedia.com